Fiber Optic Frequency Transfer Modem VCH-607

Download PDF

The VCH-607 fiber-optic modem of reference signals is designed for receiving and transmitting electrical signals with nominal frequency 100 MHz through a fiber-optic system and generating electrical signals with nominal frequencies 5 and 10 MHz, coherent with the input signal.
Reception/transmission of high precision signals via the fiber optic communication line (FOCL) is provided using a pair of modems: one is configured as a Transmitter and installed at the end of the FOCL where the signal source is located, the second – as a Receiver and installed at the opposite end of the FOCL.

Key applications:
− metrology;
− time scale comparison systems;
− production and testing of high precision oscillators and devices based on them;
− scientific research.

Specifications

Input electrical signals:
– sinusoidal: 100 MHz, root mean square (RMS) voltage value — (1 ± 0.2) V at a load of 50 ohms;
Output electrical signals:
– sinusoidal: 5 MHz, 10 MHz, 100 MHz, RMS voltage value — (1 ± 0.2) V at a load of 50 Ω;

Metrological characteristics

Averaging time, τ Allan deviation noise floor
1 s 1.0∙10 −13
10 s 2.0∙10 −14
100 s 5.0∙10 −15
1 hour 7.0∙10 −16

Dimensions (H×W×D) – 140×236×326 mm.