{"id":20735,"date":"2021-08-17T17:25:00","date_gmt":"2021-08-17T17:25:00","guid":{"rendered":"http:\/\/wordpress.vremya-ch.com\/?p=20735"},"modified":"2026-09-03T07:56:39","modified_gmt":"2026-09-03T07:56:39","slug":"vch-505-en","status":"publish","type":"post","link":"http:\/\/wordpress.vremya-ch.com\/index.php\/en\/products-en\/telecommunic-en\/vch-505-en\/","title":{"rendered":"PTP Grandmaster Clock Combiner VCH-505"},"content":{"rendered":"\n<figure class=\"wp-block-image alignright size-full is-resized\"><a href=\"\/wp-content\/uploads\/pdf-VCH-505-en.pdf\" target=\"_blank\" rel=\"noreferrer noopener\"><img loading=\"lazy\" src=\"\/wp-content\/uploads\/icon-pdfdownload.jpg\" alt=\"Download PDF\" width=\"55\" height=\"55\"><\/a><\/figure>\n\n\n\n<figure class=\"wp-block-image alignleft size-full is-resized is-style-zoooom\"><a href=\"\/wp-content\/uploads\/VCH-505.jpg\" target=\"_blank\" rel=\"noreferrer noopener\"><img src=\"\/wp-content\/uploads\/VCH-505.jpg\" alt=\"\" class=\"wp-image-19912\" width=\"400\" srcset=\"http:\/\/wordpress.vremya-ch.com\/wp-content\/uploads\/VCH-505.jpg 1300w, http:\/\/wordpress.vremya-ch.com\/wp-content\/uploads\/VCH-505-354x207.jpg 354w, http:\/\/wordpress.vremya-ch.com\/wp-content\/uploads\/VCH-505-768x449.jpg 768w\" sizes=\"(max-width: 1300px) 100vw, 1300px\" \/><\/a><\/figure>\n\n\n\n<p>The <strong>VCH-505 PTP Grandmaster Clock Combiner<\/strong> is designed to provide high-precision frequency and time synchronization in digital telecommunications networks.<br>\nIts primary application is as a <strong>precision time server for packet-switched networks<\/strong>, supporting PTP and NTP. The VCH-505 can also be deployed in SDH networks as a <strong>Transit Node Clock (TNC)<\/strong> or <strong>Local Node Clock (LNC)<\/strong>.<\/p>\n\n\n\n<p><strong>Key Features<\/strong><br>\n\u2013\tsynchronization inputs: <strong>10 \/ 2.048 MHz, BITS (E1), 1 PPS, ToD &amp; 1 PPS, SyncE, and PTPv2 Slave<\/strong>.<br>\n\u2013\tSynchronization outputs: <strong>10 \/ 2.048 MHz, 2.048 Mbit\/s, BITS (E1), 1 PPS, ToD &amp; 1 PPS, SyncE, and PTP Grandmaster<\/strong>.<br>\n\u2013\tContinuous monitoring of input synchronization signals using <strong>TE, MTIE, TDEV, \u0394f\/f <\/strong>parameters.<br>\n\u2013\tInternal DOCXO aging (frequency drift) compensation in Holdover mode (DOCXO+ option).<br>\n\u2013\tRedundant, hot-swappable power supply modules for <strong>100\u2013240 V AC or 36\u201372 V DC operation<\/strong>.<br>\n\u2013\tWhen synchronized to GNSS, the unit complies with <strong>ITU-T G.811<\/strong>.<br>\n\u2013\tOptional multi-band GNSS receiver providing compliance with <strong>ITU-T G.811.1<\/strong>.<br>\n\u2013\t<strong>Reference frequency and UTC time combining<\/strong> in accordance with <strong>ITU-T G.811.1 \/ G.8272.1<\/strong>.<br>\n\u2013\tOptional expansion modules:<br>\n\u2022\t16 additional <strong>2.048 MHz \/ 2.048 Mbit\/s outputs<\/strong>;<br>\n\u2022\t4 additional <strong>10 \/ 2.048 MHz outputs<\/strong> and 4 additional <strong>1 PPS outputs<\/strong>;<br>\n\u2022\t<strong>10GbE SFP+<\/strong> ports (x2).<br>\n\u2013\tSupports <strong>GLONASS, GPS, BeiDou, and Galileo<\/strong>.<br>\n\u2013\tGNSS <strong>spoofing detection<\/strong>.<br>\n\u2013\tCompact <strong>1U, 19-inch rack-mount<\/strong> design.<br>\n\u2013\tFour isolated <strong>1000BASE-X SFP ports<\/strong>.<br>\n\u2013\tUp to <strong>16 independent PTP\/NTP configurations per Ethernet port<\/strong>, each with its own IPv4 address.<br>\n\u2013\tVLAN tagging support.<br>\n\u2013\tTime reference reception from <strong>GNSS, ToD &amp; 1 PPS, or PTPv2 Slave<\/strong>.<br>\n\u2013\tWeb-based control\/monitoring.<br>\n\u2013\tGlobal multi-user NMS (Linux, PostgreSQL).\n<\/p>\n\n\n\n<p><strong>Main Technical Specifications<\/strong><br>\n<strong>Internal oscillator<\/strong>:<br>\nHigh-stability DOCXO with a temperature stability of <strong>\u00b15.0 \u00d7 10<sup>\u221211<\/sup><\/strong> over the +10 to +70 \u00b0C temperature range.<br>\n<strong>Optional oscillator:<\/strong><br>\nRubidium oscillator with stability up to <strong>\u00b11.0 \u00d7 10<sup>\u221210<\/sup><\/strong> over the \u221210 to +75 \u00b0C temperature range.<br>\n<strong>Maximum server clock synchronization error relative to UTC<\/strong>:<br>\n\u00b130 ns when synchronized to GPS\/GLONASS or an external 1 PPS reference.<br>\n<strong>Holdover performance after loss of GPS\/GLONASS synchronization<\/strong>, at constant ambient temperature, during the first 24 hours:<br>\n\u2013\tDOCXO: <strong>within \u00b110 \u00b5s.<\/strong><br>\n\u2013\tRubidium oscillator: <strong>within \u00b12 \u00b5s<\/strong>.<br>\n\u2013\tWhen used with the <strong>VCH-1008C hydrogen maser<\/strong> in frequency-and-time combiner mode: <strong>3 ns<\/strong>.<br>\n<strong>Management interfaces and protocols<\/strong>: HTTPS, SSH, SNMPv2.<br>\n<strong>Power supply inputs 1 and 2<\/strong>: 100\u2013240 V AC or 36\u201372 V DC, in any combination.<br>\n<strong>Power consumption<\/strong>: 40 W max.<br>\n<strong>MTBF<\/strong>: at least 120,000 hours<br>\n<strong>Service life<\/strong>:20 years.\n\n\n<\/p>\n\n\n\n<p><strong>Operating Conditions<\/strong><br>\n<strong>ambient temperature:<\/strong> +5 to +40 \u00b0C<br><strong>Relative humidity at +25 \u00b0C:<\/strong> up to 95%.<br>\n<strong>Dimensions (W \u00d7 H \u00d7 D):<\/strong>440 \u00d7 32 \u00d7 252 mm.<br>\n<strong>Weight<\/strong>: 4.2 kg max.\n<\/p>\n\n\n\n<p><strong>Standards Compliance<\/strong><br>\nThe VCH-505 supports or complies with the following telecommunications and networking standards:\n<strong>ITU-T:<\/strong>\nG.703, G.704, G.781, G.811, G.811.1, G.812, G.8261, G.8262, G.8264, G.8272, G.8273.2, G.8265.1, G.8275.1, G.8275.2.<br>\n<strong>PTP:<\/strong>IEEE 1588v2.<br>\n<strong>Ethernet \/ VLAN:<\/strong>IEEE 802.1Q, 802.1ad, 802.1p.<br>\n<strong>NTP \/ SNTP:<\/strong>RFC 1059 (NTPv1), RFC 1119 (NTPv2), RFC 1305 (NTPv3), RFC 5905 (NTPv4), RFC 4330 (SNTPv4).<br>\n<strong>Safety and EMC:<\/strong>GOST IEC 62368-1-2014<br>GOST CISPR 32-2015.\n<\/p>\n\n\n\n<p><strong>PTPv2 Capabilities<\/strong><br>\nThe VCH-505 supports IEEE 1588v2 Precision Time Protocol and provides:<br>\n\u2013 <strong>Master, Slave, and Boundary Clock (Class C)<\/strong> operating modes.<br>\n\u2013 Internal time-scale resolution of <strong>5 ns<\/strong>.<br>\n\u2013 4 isolated SFP ports (1000BASE-X).<br>\n\u2013 2 isolated 10GbE SFP+ ports option.<br>\n\u2013 PTP message addressing in <strong>unicast, multicast, and mixed modes<\/strong>.<br>\n\u2013 <strong>one-step \/ two-step<\/strong> timestamping.<br>\n\u2013 <strong>one-way \/ two-way<\/strong> operation.<br>\n\u2013 PTP transport over:<br>\n\u2022 Ethernet Layer 2;<br>\n\u2022 UDP\/IPv4 Layer 3;<br>\n\u2013 delay measurement using:<br>\n\u2022 <strong>End-to-End (E2E)<\/strong>;<br>\n\u2022 <strong>Peer-to-Peer (P2P)<\/strong>.<br>\n\u2013 <strong>Synchronous Ethernet (SyncE)<\/strong>.<br>\n\u2013 <strong>Ethernet Synchronization Messaging Channel (ESMC)<\/strong> messages.<br>\n\u2013 Support for up to <strong>1,024 PTP clients per port<\/strong> at a synchronization message rate of up to <strong>128 packets per second<\/strong>.\n<\/p>\n\n\n\n<p><strong>Supported PTP Profiles<\/strong><br>\n<strong>ITU-T G.8265.1<\/strong> \u2014 unicast, Layer 3<br>\n<strong>ITU-T G.8275.1<\/strong> \u2014 multicast, Layer 2, SyncE<br>\n<strong>ITU-T G.8275.2<\/strong> \u2014 unicast, Layer 3, SyncE<br>\nCustom profiles based on user-defined combinations of the supported parameters\n<\/p>\n\n\n\n<p><strong>NTP Server Capabilities<\/strong><br>\nThe VCH-505 supports <strong>NTPv3 and NTPv4<\/strong> in accordance with <strong>IETF RFC 1305 and RFC 5905<\/strong>.<br>\n\u2013 <strong>Stratum 1<\/strong> operation.<br>\n\u2013 Up to <strong>50,000 NTP clients per port<\/strong>.<br>\n<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized is-style-zoooom\"><a href=\"\/wp-content\/uploads\/vch-505-en-image1.jpg\" target=\"_blank\" rel=\"noreferrer noopener\"><img loading=\"lazy\" src=\"\/wp-content\/uploads\/vch-505-en-image1.jpg\" alt=\"\" width=\"584\" height=\"424\"><\/a><\/figure>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized is-style-zoooom\"><a href=\"\/wp-content\/uploads\/vch-505-en-image2.jpg\" target=\"_blank\" rel=\"noreferrer noopener\"><img loading=\"lazy\" src=\"\/wp-content\/uploads\/vch-505-en-image2.jpg\" alt=\"\" width=\"553\" height=\"320\"><\/a><\/figure>\n\n\n\n<div class=\"wp-container-3 wp-block-columns\">\n<div class=\"wp-container-1 wp-block-column\"><\/div>\n\n\n\n<div class=\"wp-container-2 wp-block-column\"><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>The VCH-505 PTP Grandmaster Clock Combiner is designed to provide high-precision frequency and time synchronization in digital telecommunications networks. Its primary application is as a precision time server for packet-switched networks, supporting PTP and NTP. The VCH-505 can also be deployed in SDH networks as a Transit Node Clock (TNC) or Local Node Clock (LNC). [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[70],"tags":[],"_links":{"self":[{"href":"http:\/\/wordpress.vremya-ch.com\/index.php\/wp-json\/wp\/v2\/posts\/20735"}],"collection":[{"href":"http:\/\/wordpress.vremya-ch.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/wordpress.vremya-ch.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/wordpress.vremya-ch.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/wordpress.vremya-ch.com\/index.php\/wp-json\/wp\/v2\/comments?post=20735"}],"version-history":[{"count":24,"href":"http:\/\/wordpress.vremya-ch.com\/index.php\/wp-json\/wp\/v2\/posts\/20735\/revisions"}],"predecessor-version":[{"id":20778,"href":"http:\/\/wordpress.vremya-ch.com\/index.php\/wp-json\/wp\/v2\/posts\/20735\/revisions\/20778"}],"wp:attachment":[{"href":"http:\/\/wordpress.vremya-ch.com\/index.php\/wp-json\/wp\/v2\/media?parent=20735"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/wordpress.vremya-ch.com\/index.php\/wp-json\/wp\/v2\/categories?post=20735"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/wordpress.vremya-ch.com\/index.php\/wp-json\/wp\/v2\/tags?post=20735"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}